AIRPEL PERFORMANCE SPECIFICATIONS - Imperial Models
(Please scroll down for metric models)

airpel_antistiction_air_cylinders Airpel Anti-Stiction Air Cylinders

Click on a model to view its data sheet, select desired options, or obtain a CAD File.

MODEL
E9 E16 E24
BORE (inches)
NOTE: 1.281" Bore Available in Metric
.366 .627 .945
PISTON AREA (sq. inch)
.105 .307 .701
PRESSURE RANGE: FULL VACUUM TO - (PSI)
100 100 100
FORCE OUTPUT AT MAX PRESSURE ON REAR SIDE (lbs)
10.5 30.70 70.1
FORCE OUTPUT AT MAX PRESSURE ON ROD SIDE (lbs) 9.3 27.60 65.2
FORCE FACTOR REAR SIDE
(factor x pressure=force output)
.105 .307 .701
FORCE FACTOR ROD SIDE
(factor x pressure=force output)
.093 .276 .652
MIN PRESSURE DIFFERENTIAL REQD FOR ACTUATION (PSI) <.2 <.2 <.2
PISTON FRICTION AS % OF LOAD
(without side load)
1%-2% 1%-2% 1%-2%
OPERATING TEMPERATURE RANGE -55° C to +150° C -55° C to +150° C -55° C to +150° C
WEIGHT OF PISTON/ROD ASSY ONLY (grams)
     
Single rod end models
Double rod end models
4.5+(1.36 x STROKE)
9.93+(3.24 x STROKE)
16+(3.6 x STROKE)
29.08+(8.00 x STROKE)
40.64+(6.46 x STROKE)
73.28+(12.92 x STROKE)
WEIGHT OF COMPLETE UNIT (grams)
     
Single rod end models
Double rod end models
31.7+(9.52 x STROKE)
38.46+(11.74 x STROKE)
64.6+(15.8 x STROKE)
84.49+(21.68 x STROKE)
156.42+(31.12 x STROKE)
203.9+(37.58 x STROKE)
MAX LEAK AT REFERENCE PRESSURES
 
AT PRESSURE PSI=
50 50 50
MAX LEAK RATE by Piston: SL / min
1.16 1.39 2.2
MAX LEAK RATE by Rod: SL / min
2.2 2.6 2.6
*NOTE: Lower leak rates are available upon request. Please consult an applications engineer.

 

AIRPEL PERFORMANCE SPECIFICATIONS - Metric Models

airpel_M_family Airpel Anti-Stiction Air Cylinders

MODEL
M9 M16 M24 M32
BORE (mm)
9.3 15.9 24.0 32.5
PISTON AREA (sq. mm)
67.7 198 452.5 830
MAX PRESSURE: (MPa)
0.7 0.7 0.7 0.7
SUITABLE FOR VACUUM ACTUATION?
Yes Yes Yes No
FORCE OUTPUT AT MAX PRESSURE ON REAR SIDE (Newtons)
47.4 139 316.6 581
FORCE OUTPUT AT MAX PRESSURE ON ROD SIDE (Newtons) 42.0 125 294.5 526
Force factor Rear Side
(factor x pressure(MPa)=
force output (N))
67.7 198 452.5 830
Force factor Rod Side
(factor x pressure(MPa)=
force output (N))
60.0 178 420.8 751
MIN PRESSURE DIFFERENTIAL REQD FOR ACTUATION (MPa) < 0.0015 < 0.0015 < 0.0015 < 0.0035
PISTON FRICTION (without side load)
AS % OF LOAD
1%-2% 1%-2% 1%-2% 1%-2%
OPERATING TEMPERATURE RANGE -55° C to +150° C -55° C to +150° C -55° C to +150° C -55° C to +150° C
WEIGHT OF PISTON/ROD ASSY (grams)
       
Single rod end models
Double rod end models
4.5+(0.053 x STROKE)
8.87+(0.13 x STROKE)
16+(0.142 x STROKE)
28.48+(0.315 x STROKE)
41.4+(0.254 x STROKE)
74.28+(.509 x STROKE)
82.6+(0.56 x STROKE)
WEIGHT OF COMPLETE UNIT (grams)
       
Single rod end models
Double rod end models
31.7+(0.375 x STROKE)
41.02+(0.462x STROKE)
64.6+(0.622 x STROKE)
80.45+(0.854 x STROKE)
157.18+(1.225 x STROKE)
204.9+(1.480 x STROKE)
616+(3.66 x STROKE)
MAX LEAK AT REFERENCE PRESSURES
AT PRESSURE MPa=
0.34 0.34 0.34 0.34
MAX LEAK RATE by Piston: SL / min
1.16 1.39 2.2 2.2
MAX LEAK RATE by Rod: SL / min
2.2 2.6 2.6 2.0
*NOTE: Lower leak rates are available upon request. Please consult an applications engineer.